LOW / MEDIUM POWER |
|
HERON Series

Model: HN 11, HN 21, HN 31
Double Conversion Online UPS
Rating :
1 KVA, 2 KVA, 3 KVA |
|
Single Phase Input & Output. |
|
Salient Features:-
• Wide input voltage window
• Input power factor near unity
• Controlled input current harmonic level
• High overall efficiency
• 48 VDC operated
(suitable for Telecom application)
• Cold Start facility |
|
|
|
|
LNux Series

Model: LNux31, 51, 61
Double Conversion Online UPS
Rating :
3 KVA to 6 KVA |
|
Single phase input & online |
|
Salient Features:-
• Input power factor near unity
• Controlled input current harmonic level
• High overall efficiency
• Cold start facility
• Powerful battery charger |
|
TOP |
|
|
LINE INTERACTIVE UPS |
|
EU Series

Model : EU 07, EU 12, EU
20\
Rating : 700 VA, 1200 VA, 2000 VA |
|
Single phase Input & Output |
|
• Wide input voltage range
• Built in AVR & strong battery charger
• Supports PCs as well as lighting loads
• Suitable for longer backups |
|
|
|
Meru Series

Model : MERU 05, MERU 10,
MERY 15
Rating : 500 W, 1000 W, 1500 W |
|
Single
phase input & Output |
|
• Wide input voltage range
• Powerful battery charger for quick charging of batteries
(for longer backups)
• Loads with higher inrush currents are well supported. |
TOP |
|
|
LN and MF Series

Double Conversion Online UPS
Model : LN 71 to LN 301
Rating : 7.5 KVA to 30 KVA
Model : MF 140 to MF 160 & MF 340 to MF
360
Rating : 40 KVA to 60 KVA
|
LN
-Three phase input, Single Phase output
MF - Three phase input, Single phase Three phase output
• Microprocessor controlled.
• Advanced rectifier design with SMPS charger
• High Input Power factor.
• State of the art technology with instantaneous sine we
control
• Better efficiency.
• SNMP & BMS compatibility.
TOP |
| |
|
HIGH POWER / CUSTOM
BUILT |
|
|
IM Series

Three phase input & Single phase output
Model : IM 180 to IM 1120
Rating : 80, 100, 120, 125 KVA
Three phase input & Three phase output
Model : IM 380 to IM 3200
Rating : 80, 100, 120, 150, 200 KVA
30 to 60 KVA : (3 Ph I/p, 1 Ph O/P upto 125 KV & 3 Ph I/P, 3
Ph O/P for 30 to 60 KVA) Employing advanced 6 pulse Rectifier
with Buck-boost SMR.
Battery charger and 7% Input current harmonic filter.
60 to 150 KVA : The UPSs employing 12
pulse Rectifier, with features like Input power factor better
than 0.96, 5% Input current harmonic filter. |
MEGA Series

Three Phase input & Three phase output.
Model : MEGA 250 to MEGA 500
Rating : 250, 300, 400, 500 KVA
Suitable for Server farms, Data Centers, Call Centers &
Industrial Process applications
Six such modules can be paralleled, which makes the total
capacity of the UPS systems as 3000 KVA.
TOP
|
|
|
Custom Built UPS for Projects

DB
offers UPS solutions which are designed for specific
requirement. These UPSs are tested & approved by renowned
project consultants like EIL, TCE, ALSTOM, UHDE, ABB, MECON,
BHEL, Techno Mont ICB, DESEIN, Kvaerner Power gas, L&T and are
used for various Process Instrumentation & Automation
applications.
These systems are supporting utmost critical
Nuclear power projects or Nuclear Power Corporatin LTD.
DB offers complete power protection with solutions like N+1
redundancy, hot standby, critical non-critical load sharing.
They are designed to have lower initial investment with 100%
power backup. These solutions offer a perfect balance between
critical power need and cost of ownership.
TOP |
|
|
GREEN POWER |
 |
Three Phase input Single
Phase output
Model : HARMONY 320 to HARMONY 3120
Rating : 10 KVA to 40 KVAThree Phase input Three Phase
output
Rating : 20 KVA to 120 KVA |
|
• Double conversion online design philosophy
• State of the Art PWM rectifier
• Input power factor near unity (>0.99) independent of input
voltage variation.
• Input current harmonic distortion less than 3%
• Exceptional performance on non-linear loads
• Input to output galvanic isolation
• Generator rating required is only 10% higher than that of UPS
input power rating
• Superior dynamic response.
TOP |
|
|
|
INSTA
SWITCH |
|

Available
in 3 & 6 KVA ratings. This switch provides redundancy up to load
point when fed from TWO independent synchronised power sources (UPSs).
It has connection terminal as well as the Control Logic. The
switch fits in to the 19" rack. These are most useful for the
critical applications like ; Server farms, Data Centers, Call
Centers etc.
TOP |
|
LN & SYNERGY
UPS
|
LN
3100/3300 |

10 to 40 kVA UPS
Three Phase input, Single/Three phase Output |
|
• Double conversion online UPS
• Advanced rectifier design
• High input power factor
• State of the Art digital control
• Network connectivity
• Compliance to International standards |
|
|
Synergy 3100/3300 |

60 to 300 kVA UPS
Three Phase Input, Single/Three Phase Output |
|
• Double Conversion online UPS
• Advanced Power factor compensated rectifier
• High input power factor
• Digital control
• Network connectivity
• Compliance to International standards |
|
TOP |
|
|